{"id":25774,"date":"2022-02-04T15:44:53","date_gmt":"2022-02-04T20:44:53","guid":{"rendered":"https:\/\/westpenetone.com\/?page_id=25774"},"modified":"2022-02-08T10:00:30","modified_gmt":"2022-02-08T15:00:30","slug":"post-operational-cleaning","status":"publish","type":"page","link":"https:\/\/westpenetone.com\/en\/post-operational-cleaning\/","title":{"rendered":"Overview of Post-Operational Cleaning"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\"  style='background-color: rgba(255,255,255,0);background-position: center center;background-repeat: no-repeat;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;'><div class=\"fusion-builder-row fusion-row \"><div  class=\"fusion-layout-column fusion_builder_column fusion_builder_column_3_5 fusion-builder-column-0 fusion-three-fifth fusion-column-first 3_5\"  style='margin-top:0px;margin-bottom:0px;width:58.4%; margin-right: 4%;'><div class=\"fusion-column-wrapper\" style=\"padding: 0px 0px 0px 0px;background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;\"   data-bg-url=\"\"><div class=\"fusion-text\"><p>The primary goal of post-operational cleaning in refinery and petrochemical plants is to decontaminate and degas a unit or process vessel. This involves removing bulk foulant and solid debris from the unit while simultaneously freeing it of hazardous gas contaminants. This process is completed during shutdowns or turnarounds to provide fast, efficient, and safe entry for purposes of maintenance or inspection.<\/p>\n<p>To accomplish this goal, procedures need to be developed that implement either a liquid circulation or a vapor-phase co-injection to distribute a chemical cleaning product inside the unit. Other methods of application exist, including purging or foam blanketing, but they tend to target only gas contaminants. Regardless of method, the procedure must apply the appropriate chemistries is such a way as to promote both efficient and effective operations and schedules in the decontamination and degasification process.<\/p>\n<p>Efficient and effective application of a chemical cleaning program may involve a single-step, multi-step, or combinational process. A single-step procedure involves the injection of only one chemical product at various injection points. Multi-step procedures involve the injection of a sequence or progression of chemical products to mitigate fouling and contamination issues alleviated by products not fully compatible upon direct mixing. That is, they may neutralize each other, cause degradation and loss of activity, etc. This procedure typically occurs at one main injection point. Combinational procedures involve injecting more than one chemical product to mitigate fouling and contamination issues that can be remediated by products capable of being mixed at the point of application. The latter two procedures are adopted when complex fouling is present or when a one-pack product lacks the activity to address higher degrees of fouling or gas contamination.<\/p>\n<p>Overall, combined with sufficient heat and agitation, a proper chemical cleaning program will assist in full dissolution of the bulk contamination. Typically, the product or products will be chosen when the contamination has been characterized and located within the vessel or unit. The method of application, as discussed above, will have some influence in this choice as well.<\/p>\n<p>Some of the products to review for removing bulk solids and contaminants are listed below with a brief description:<\/p>\n<ul>\n<li><strong>PENBLITZ 688L<\/strong> \u2013 alkaline degreaser concentrate used for mobilizing asphaltenes, iron sulfide and sludge residuals in liquid circulation procedures<\/li>\n<li><strong>CITRIKLEEN HD<\/strong> \u2013 industrial degreaser used for various metal surface cleaning applications in both liquid circulation and vapor-phase co-injection procedures<\/li>\n<li><strong>RAMSOL BCX<\/strong> \u2013 solvent degreaser used for mobilizing asphaltenes and resins in liquid circulation procedures<\/li>\n<li><strong>RAMSOL HD<\/strong> \u2013 solvent degreaser used in nitrogen purge procedures requiring the removal of hydrocarbon sludge and H<sub>2<\/sub>S<\/li>\n<\/ul>\n<p>Some of the products to review for targeting a spectrum of gas contaminants are listed below:<\/p>\n<ul>\n<li><strong>ROC 40<\/strong> \u2013 enzyme-based cleaner and degasification aid<\/li>\n<li><strong>ROC 45<\/strong> \u2013 surfactant-based cleaner and degasification aid<\/li>\n<li><strong>ROC 60VP<\/strong> \u2013 high-temperature stable hydrogen sulfide scavenger and degasification aid<\/li>\n<\/ul>\n<p>All the products will assist in mitigating benzene, LEL, and H<sub>2<\/sub>S as well as iron sulfides. When applied at the appropriate concentration, the degassing product line produces a micellar solution that allows for higher solubility of hydrocarbon gases into the bulk liquid. Models suggest that high mol fractions of low molecular weight gases can be captured translating to approximately 400-600 ppm<sub>v<\/sub> per liter of micellar solution.<\/p>\n<p>Should hydrogen sulfide present the more significant hazard, products to review for targeting it are listed below with a brief description:<\/p>\n<ul>\n<li><strong>SCAVEX<\/strong> \u2013 sulfide scavenger useful for chemical circulation procedures in combination with ROC products or on its own in a single-step application.<\/li>\n<li><strong>SCAVEX VP<\/strong> \u2013 thermally-stable sulfide scavenger useful for high temperature applications or circulations as well as in vapor-phase co-injection<\/li>\n<li><strong>SCAVEX AG<\/strong> \u2013 acid-stable sulfide scavenger and alternative to triazine and formaldehyde-based formulations<\/li>\n<\/ul>\n<p>Once a method of application and an appropriate product listing has been identified, procedure development is initiated in line with the stakeholder\u2019s desired or expected outcomes.<\/p>\n<p>This process involves a thorough risk assessment to lay out the necessary steps required to complete the chemical cleaning efficiently and effectively. The complete process is outlined below:<\/p>\n<ul>\n<li><strong>Risk Assessment<\/strong>\n<ul>\n<li>Hazards review \u2013 e.g., hot liquids, compatibility, burns\/spills, toxic vapors, or oxygen deficiency at vent points, etc.<\/li>\n<li>Steps to mitigate operational hazards<\/li>\n<\/ul>\n<\/li>\n<li><strong>Method Assessment &amp; Procedure Development<\/strong>\n<ul>\n<li>Vessel survey \u2013 PID\u2019s, foulant location, previous products and method of application employed, previous cleaning results, etc.?<\/li>\n<li>Foulant characterization \u2013 is a sample available for solubility testing?<\/li>\n<li>Gas contaminants \u2013 e.g., estimated or measured concentrations?<\/li>\n<li>Method Implementation \u2013appropriate injection and drainage points, identification of circulation loops, sampling points, etc.<\/li>\n<li>Retain monitoring \u2013 periodic detection of contaminants, product concentration, etc.<\/li>\n<li>Disposal Assessment<\/li>\n<li>Waste restrictions \u2013 water treatment, disposal, etc.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep sep-none\" style=\"margin-left: auto;margin-right: auto;margin-top:17px;margin-bottom:15px;\"><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div  data-animationType=fadeInRight data-animationDuration=0.3 data-animationOffset=100% class=\"fusion-layout-column fusion_builder_column fusion_builder_column_2_5 fusion-builder-column-1 fusion-two-fifth fusion-column-last fusion-animated 2_5\"  style='margin-top:0px;margin-bottom:0px;width:37.6%'><div class=\"fusion-column-wrapper\" style=\"padding: 0px 0px 0px 0px;background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;\"   data-bg-url=\"\"><span class=\"fusion-imageframe imageframe-none imageframe-1 hover-type-none img-100-percent fusion-animated\" data-animationType=\"fadeInLeft\" data-animationDuration=\"0.9\" data-animationOffset=\"50%\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/westpenetone.com\/wp-content\/uploads\/post_op-2.png\" width=\"700\" height=\"345\" alt=\"Fluid Separation and Treatment\" title=\"post_op\" class=\"img-responsive wp-image-25781\" srcset=\"https:\/\/westpenetone.com\/wp-content\/uploads\/post_op-2-200x99.png 200w, https:\/\/westpenetone.com\/wp-content\/uploads\/post_op-2-400x197.png 400w, https:\/\/westpenetone.com\/wp-content\/uploads\/post_op-2-600x296.png 600w, https:\/\/westpenetone.com\/wp-content\/uploads\/post_op-2.png 700w\" sizes=\"auto, (max-width: 990px) 100vw, 700px\" \/><\/span><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep sep-none\" style=\"margin-left: auto;margin-right: auto;margin-top:20px;\"><\/div><div class=\"fusion-button-wrapper fusion-align-block\"><style type=\"text\/css\">.fusion-button.button-1 .fusion-button-text, .fusion-button.button-1 i {color:#ffffff;}.fusion-button.button-1 .fusion-button-icon-divider{border-color:#ffffff;}.fusion-button.button-1:hover .fusion-button-text, .fusion-button.button-1:hover i,.fusion-button.button-1:focus .fusion-button-text, .fusion-button.button-1:focus i,.fusion-button.button-1:active .fusion-button-text, .fusion-button.button-1:active{color:#0677bd;}.fusion-button.button-1:hover .fusion-button-icon-divider, .fusion-button.button-1:hover .fusion-button-icon-divider, .fusion-button.button-1:active .fusion-button-icon-divider{border-color:#0677bd;}.fusion-button.button-1:hover, .fusion-button.button-1:focus, .fusion-button.button-1:active{border-color:#0677bd;border-width:1px;}.fusion-button.button-1 {border-color:#0677bd;border-width:1px;border-radius:8px;}.fusion-button.button-1{background: #0677bd;}.fusion-button.button-1:hover,.button-1:focus,.fusion-button.button-1:active{background: #cde4f2;}.fusion-button.button-1 .fusion-button-text {text-transform:uppercase;}<\/style><a class=\"fusion-button button-flat button-xlarge button-custom button-1 fusion-button-span-yes fusion-button-default-type\" target=\"_self\" href=\"https:\/\/westpenetone.com\/en\/knowledge\"><i class=\"fa-book-open fas button-icon-left\"><\/i><span class=\"fusion-button-text\">Back to Knowledge Center<\/span><\/a><\/div><div class=\"fusion-widget-area fusion-widget-area-1 fusion-content-widget-area\"><style type=\"text\/css\">.fusion-widget-area-1 {padding:0px 0px 0px 0px;}.fusion-widget-area-1 .widget h4 {color:#212934;}.fusion-widget-area-1 .widget .heading h4 {color:#212934;}<\/style><section id=\"search-4\" class=\"widget widget_search\" style=\"border-style: solid;border-color:transparent;border-width:0px;\"><div class=\"heading\"><h4 class=\"widget-title\">Products search<\/h4><\/div>\t\t<form role=\"search\" class=\"searchform fusion-search-form  fusion-search-form-clean\" method=\"get\" action=\"https:\/\/westpenetone.com\/en\/\">\n\t\t\t<div class=\"fusion-search-form-content\">\n\n\t\t\t\t\n\t\t\t\t<div class=\"fusion-search-field search-field\">\n\t\t\t\t\t<label><span class=\"screen-reader-text\">Search for:<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<input type=\"search\" value=\"\" name=\"s\" class=\"s\" placeholder=\"Search...\" required aria-required=\"true\" aria-label=\"\"\/>\n\t\t\t\t\t\t\t\t\t\t\t<\/label>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"fusion-search-button search-button\">\n\t\t\t\t\t<input type=\"submit\" class=\"fusion-search-submit searchsubmit\" value=\"&#xf002;\" \/>\n\t\t\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\n\t\t\t<\/div>\n\n\n\t\t\t\n\t\t<\/form>\n\t\t<\/section>\n\t\t<section id=\"recent-posts-3\" class=\"widget widget_recent_entries\" style=\"border-style: solid;border-color:transparent;border-width:0px;\">\n\t\t<div class=\"heading\"><h4 class=\"widget-title\">Recent news<\/h4><\/div>\n\t\t<ul>\n\t\t\t\t\t\t\t\t\t\t\t<li>\n\t\t\t\t\t<a href=\"https:\/\/westpenetone.com\/en\/year-end-inventory\/\">Year end inventory<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t\t\t\t<li>\n\t\t\t\t\t<a href=\"https:\/\/westpenetone.com\/en\/west-penetone-in-italy-mission\/\">West Penetone in Italy mission!<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t\t\t\t<li>\n\t\t\t\t\t<a href=\"https:\/\/westpenetone.com\/en\/ultrasonic-cleaning\/\">Ultrasonic Cleaning<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t<\/ul>\n\n\t\t<\/section><div class=\"fusion-additional-widget-content\"><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":12,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-25774","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/westpenetone.com\/en\/wp-json\/wp\/v2\/pages\/25774","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/westpenetone.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/westpenetone.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/westpenetone.com\/en\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/westpenetone.com\/en\/wp-json\/wp\/v2\/comments?post=25774"}],"version-history":[{"count":4,"href":"https:\/\/westpenetone.com\/en\/wp-json\/wp\/v2\/pages\/25774\/revisions"}],"predecessor-version":[{"id":25783,"href":"https:\/\/westpenetone.com\/en\/wp-json\/wp\/v2\/pages\/25774\/revisions\/25783"}],"wp:attachment":[{"href":"https:\/\/westpenetone.com\/en\/wp-json\/wp\/v2\/media?parent=25774"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}